Evaluation of the diagnostic performances of two commercially available assays for the detection of enteric adenovirus antigens

2021

The performance of 2 antigenic commercial assays for enteric adenovirus (AdV) infection, bioNexia Rota-Adeno ImmunoChromatographic Tests (ICT) and LIAISON® Adenovirus ChemiLuminescence Immuno Assays (CLIA), was evaluated on 321 stools from children hospitalized for acute gastroenteritis in Palermo, Italy, using a Real time-PCR (Rt-PCR) as reference method. The CLIA showed higher sensitivity (77% vs 60%), accuracy (94.4 vs 90.9) and concordance (k: 0.81 vs 0.67) with respect to ICT, despite equivalent specificity (98.8%). Using the Ct values of the Rt-PCR as a proxy of the fecal viral load, similar Ct values (mean 9.32 vs 9.89) were observed among the true positive samples, whilst a signific…

Microbiology (medical)medicine.medical_specialtySettore MED/07 - Microbiologia E Microbiologia ClinicaAdolescentAdenoviridae InfectionsConcordanceSensitivity and SpecificityGastroenterologyAdenoviridaeFecesAntigenChemiluminescent immunoassayInternal medicineFecal antigens detectionmedicineHumansChemiluminescent immunoassayChildAntigens ViralFecesImmuno chromatographyAcute gastroenteritibusiness.industrySignificant differenceInfant NewbornEnteric adenoviruseInfantGeneral MedicineAcute gastroenteritisGastroenteritisHospitalizationInfectious DiseasesItalyChild PreschoolLuminescent MeasurementsReagent Kits DiagnosticDiagnostic performancebusinessViral load